The Built-In 2F control unit is a control system for managing two loads.
Built-In 2F Pump-Blower was designed for pump and blower control.
Technical features:
- Power supply: 230Vac 50/60Hz
- Outputs:
Load 1 (Blower) -> 230Vac 1Hp
Load 2 (Pump) -> 230Vac 1Hp - Provides management of the level sensor (included) and time-out
- Compatible interfaces: ONE.KI single, ONE.KI double and TM04 mechanical button
OPERATION IGNITION After powering the control unit, after 3 seconds the system is ready for use. – RED LED indicates that there is no water (STAND-BY) – FLASHING GREEN LED indicates that the tub is ready for use (minimum water level reached) HYDROMASSAGE FUNCTION (PUMP) – Operation: press the corresponding button. The GREEN LED is ON – Switching off: press the button or wait for automatic switch-off (45min) ATTENTION: if the safety sensor does not detect the presence of water for more than 3 seconds, all the loads are deactivated AIRPOOL FUNCTION (BLOWER) – Activation: press the corresponding button. The GREEN LED is ON – Switching off: press the button or wait for automatic switch-off (45min) PIPES DRYING FUNCTION (BLOWING AFTER) In order to avoid water stagnation in the pipes, an automatic drying function is provided. ACTIVATION METHOD: – Wait 30 minutes from the absence of water level in the tub: the blower switches on automatically for 5 minutes – Activate the blower manually when the tub is empty by pressing the blower button for 5 seconds During the function, the GREEN LED is ON. To block the drying function: – press the blower button for 5 seconds with the function active – wait for the 5-minute time-out When the function is complete, the LED turns RED.